2600 STUD LENGTH SELECTION
Total material thickness “G” consists of the thickness of all materials to be fastened. This must include the thickness of the material “P” to which the stud assembly is attached, the material “F” to which the receptacle is attached plus gaskets (if used) and allowance for paint or other protective finishes. If the total thickness is near the upper limit of the stud grip range, the next longer stud should be used. This will still maintain positive locking of the fastener under vibration. 

P (panel thickness)..................... .062
F (frame thickness................... + .062
GRIP (total thickness).............. = .124

/

STUD SELECTION TABLE
Using 212-12 Receptacle
Total Grip Thickness
Use 2600
.020-.059
2600-1
.060-.089
2600-2
.090-.119
2600-3
.120-.149
2600-4
.150-.179
2600-5
.180-.209
2600-6
.210-.239
2600-7
.240-.269
2600-8
.270-.299
2600-9
.300-.329
2600-10
.330-359
2600-11
.360-389
2600-12
.390-.419
2600-13
.420-.449
2600-14
2600-6